{"id":172760,"date":"2026-04-13T19:00:00","date_gmt":"2026-04-13T17:00:00","guid":{"rendered":"https:\/\/www.icareweb.com\/knowledge\/preventing-hvac-fan-failure-pharma-vibration-analysis-predictive-maintenance\/"},"modified":"2026-11-04T13:49:55","modified_gmt":"2026-11-04T12:49:55","slug":"preventing-hvac-fan-failure-pharma-vibration-analysis-predictive-maintenance","status":"publish","type":"resource","link":"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/prevention-panne-ventilateur-cvc-pharmaceutique-analyse-vibratoire-maintenance-predictive\/","title":{"rendered":"Comment l\u2019analyse vibratoire a permis d\u2019\u00e9viter une panne critique d\u2019un ventilateur CVC dans une usine pharmaceutique"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull icare-hero is-style-shade-left-top has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background:linear-gradient(135deg,rgb(247,248,253) 0%,rgba(247,248,252,0.49) 100%);margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--medium);padding-bottom:var(--wp--preset--spacing--xx-large);--octopods-group-overlay-color:#27498C;--octopods-group-overflow:hidden;--octopods-group-position:relative\">\n<div style=\"height:180px\" aria-hidden=\"true\" class=\"wp-block-spacer block-visibility-hide-small-screen\"><\/div>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer block-visibility-hide-large-screen block-visibility-hide-medium-screen\"><\/div>\n\n\n\n<div class=\"wp-block-group icare-hero__content is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-33ae0263 wp-block-group-is-layout-flex\" style=\"min-height:35vh;--octopods-group-z-index:2;aspect-ratio:unset;\">\n<div class=\"wp-block-columns are-vertically-aligned-center is-style-columns-reverse wp-container-content-9cfa9a5a is-layout-flex wp-container-core-columns-is-layout-c603695b wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-container-core-column-is-layout-1d6b69b5 wp-block-column-is-layout-flow\" style=\"flex-basis:50%\" data-aos=\"fade\" data-aos-duration=\"900\" data-aos-easing=\"ease-in-out\" data-aos-once=\"true\"><div class=\"taxonomy-post-cat has-link-color wp-elements-1 wp-block-post-terms has-text-color has-primary-color has-medium-font-size\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div>\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-01451674 wp-block-group-is-layout-flex\" style=\"padding-right:35px\">\n<h1 class=\"wp-block-heading has-xxx-large-font-size\"><strong><strong>Comment l\u2019analyse vibratoire a permis d\u2019\u00e9viter une panne critique d\u2019un ventilateur CVC dans une usine pharmaceutique<\/strong><\/strong><\/h1>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-secondary-color has-alpha-channel-opacity has-secondary-background-color has-background is-style-default\"\/>\n\n\n\n<div class=\"wp-block-group has-primary-color has-text-color has-link-color wp-elements-2 is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\" style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.531), 1.3rem);\">\n<div class=\"wp-block-group is-horizontal is-nowrap is-layout-flex wp-container-core-group-is-layout-d85dc538 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-getwid-icon\"><div class=\"wp-block-getwid-icon__wrapper\" style=\"font-size:25px;padding:0px\"><i class=\"ph-duotone ph-engine\"><\/i><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c9quipement : Ventilateur centrifuge \u00e0 entra\u00eenement par courroie (CVC)<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-horizontal is-nowrap is-layout-flex wp-container-core-group-is-layout-d85dc538 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-getwid-icon\"><div class=\"wp-block-getwid-icon__wrapper\" style=\"font-size:25px;padding:0px\"><i class=\"ph-duotone ph-device-mobile-speaker\"><\/i><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Technologie : Analyse vibratoire<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-461897f4 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-getwid-icon\"><div class=\"wp-block-getwid-icon__wrapper\" style=\"font-size:25px;padding:0px\"><i class=\"ph-duotone ph-cpu\"><\/i><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Surveillance : Wi-care\u2122 | I-see\u2122<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\" data-aos=\"fade-right\" data-aos-duration=\"900\" data-aos-easing=\"ease-in-out\" data-aos-once=\"true\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"border-radius:20px;--octopods-group-position:relative\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1440\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-scaled.jpg\" alt=\"Centrifugal Fan Technical Case Global Illustration\" class=\"wp-image-99106\" style=\"border-radius:20px;box-shadow:var(--wp--preset--shadow--natural);aspect-ratio:3\/2;object-fit:cover\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-scaled.jpg 2560w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull icare-hero__divider is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0px;margin-bottom:0px;--octopods-group-position:absolute;--octopods-group-bottom:0px;--octopods-group-left:0px;--octopods-group-right:0px\">\n<div style=\"min-height:350px;margin-top:0px;--octopods-divider-shape-color:#ffffff;--octopods-divider-icon-color:;--octopods-divider-icon-size:20px;--octopods-divider-icon-align:center;--octopods-divider-icon-justify:center\" class=\"wp-block-octopods-divider alignfull\"><div class=\"wp-block-octopods-divider__shape\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" class=\"angle_svg__octopods-divider-svg angle_svg__octopods-divider-svg--angle\" preserveAspectRatio=\"none\" viewBox=\"0 0 1620 188.5\"><path d=\"M0 188.5h1620V0L0 183.4z\"><\/path><\/svg><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-style-shade-left has-global-padding is-layout-constrained wp-container-core-group-is-layout-ebb5ee42 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--x-large);--octopods-group-overlay-color:#F7F8FD\">\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-c603695b wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1.jpg\" alt=\"Belt-driven centrifugal fan of a HVAC in a Pharma Plant\" class=\"wp-image-100144\" style=\"border-radius:20px\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/belt-driven-centrifugal-fan-hvac-pharma-plant-01-v1-1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-850c68bf wp-block-group-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<h2 class=\"wp-block-heading has-text-align-left\">Pr\u00e9sentation de l\u2019\u00e9quipement<\/h2>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">L\u2019\u00e9quipement surveill\u00e9 est un ventilateur centrifuge \u00e0 entra\u00eenement par courroie int\u00e9gr\u00e9 \u00e0 un syst\u00e8me critique de chauffage, ventilation et climatisation (CVC) au sein d\u2019une usine de production pharmaceutique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ce ventilateur assure une circulation contr\u00f4l\u00e9e de l\u2019air dans la zone de production, garantissant le maintien des conditions requises en salle blanche et le respect des normes strictes en mati\u00e8re d\u2019environnement et de qualit\u00e9 propres \u00e0 <a href=\"https:\/\/www.icareweb.com\/fr\/industries\/pharma\/\">l\u2019industrie pharmaceutique<\/a>. Tout arr\u00eat impr\u00e9vu risquerait de compromettre ces conditions et d\u2019entra\u00eener des interruptions de production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le syst\u00e8me se compose d\u2019un moteur \u00e9lectrique de 11 kW \u00e0 4 p\u00f4les, tournant \u00e0 1 500 tr\/min, qui entra\u00eene le ventilateur par une transmission \u00e0 courroie. Le ventilateur fonctionne ainsi \u00e0 une vitesse d\u2019environ 1 630 tr\/min.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compte tenu de son r\u00f4le essentiel dans le maintien des conditions contr\u00f4l\u00e9es de production, le ventilateur doit fonctionner en continu pendant les op\u00e9rations. La d\u00e9tection pr\u00e9coce des d\u00e9faillances est donc indispensable pour \u00e9viter les arr\u00eats impr\u00e9vus et permettre de planifier les interventions de maintenance sans perturber la production.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-style-shade-right has-global-padding is-layout-constrained wp-container-core-group-is-layout-d0dbc7a1 wp-block-group-is-layout-constrained\" style=\"padding-top:var(--wp--preset--spacing--x-large);padding-bottom:var(--wp--preset--spacing--large);--octopods-group-overlay-color:#DEE0EA\">\n<div class=\"wp-block-columns are-vertically-aligned-center is-style-columns-reverse is-layout-flex wp-container-core-columns-is-layout-c603695b wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-850c68bf wp-block-group-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<h2 class=\"wp-block-heading has-text-align-left\">Installation des dispositifs de surveillance et du logiciel<\/h2>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">Les ing\u00e9nieurs en fiabilit\u00e9 d\u2019I-care ont install\u00e9 des <a href=\"https:\/\/www.icareweb.com\/fr\/solutions\/maintenance-predictive\/capteurs\/\">capteurs de vibrations sans fil Wi-care\u2122<\/a> sur le moteur et le ventilateur afin d\u2019assurer une surveillance continue de l\u2019\u00e9tat m\u00e9canique du syst\u00e8me.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019installation comprenait deux capteurs sur le moteur et deux sur le ventilateur, positionn\u00e9s de mani\u00e8re \u00e0 mesurer les vibrations au niveau de la cha\u00eene de transmission et des paliers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les capteurs transmettaient les donn\u00e9es \u00e0<a href=\"https:\/\/www.icareweb.com\/fr\/solutions\/maintenance-predictive\/plateforme\/\"> I-see\u2122, le logiciel de maintenance pr\u00e9dictive (PdM) d\u2019I-care.<\/a> I-see\u2122 traite et cat\u00e9gorise automatiquement les donn\u00e9es re\u00e7ues afin de d\u00e9tecter tout \u00e9cart par rapport aux conditions normales de fonctionnement et de signaler les premiers signes \u00e9ventuels de d\u00e9gradation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ces indicateurs sont ensuite analys\u00e9s par les sp\u00e9cialistes d\u2019I-care, qui valident les r\u00e9sultats, \u00e9tablissent un diagnostic et formulent des recommandations concr\u00e8tes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les informations ainsi obtenues sont regroup\u00e9es dans des rapports de diagnostic afin de faciliter la prise de d\u00e9cision en mati\u00e8re de maintenance.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/www.icareweb.com\/fr\/book-a-meeting\/\"><mark>Planifiez une d\u00e9mo<\/mark><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-getwid-images-stack is-layout-zeta\"><div class=\"wp-block-getwid-images-stack__wrapper\"><div class=\"wp-block-getwid-images-stack__chunk\"><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1152\" class=\"wp-block-getwid-images-stack__media wp-image-22985\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01.jpg\" data-id=\"22985\" data-link=\"https:\/\/www.icareweb.com\/wi-care-g23-in-caps-01\/\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-1280x768.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-600x360.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-768x461.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-1536x922.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-1200x720.jpg 1200w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/wi-care-g23-in-caps-01-1800x1080.jpg 1800w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/div><\/div><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" class=\"wp-block-getwid-images-stack__media wp-image-22895\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1920x1280.jpg\" data-id=\"22895\" data-link=\"https:\/\/www.icareweb.com\/solutions\/industrial-performance\/reliability-engineering\/continuous-improvement\/i-care-25\/\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1920x1280.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1280x853.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-600x400.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-768x512.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1536x1024.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1200x800.jpg 1200w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02-1620x1080.jpg 1620w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/team-02.jpg 2048w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/div><\/div><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" class=\"wp-block-getwid-images-stack__media wp-image-22871\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01.jpg\" data-id=\"22871\" data-link=\"https:\/\/www.icareweb.com\/i-see-tablet-01\/\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-1280x853.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-600x400.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-768x512.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-1536x1024.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-1200x800.jpg 1200w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/09\/i-see-tablet-01-1620x1080.jpg 1620w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/div><\/div><\/div><\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-style-shade-right has-global-padding is-layout-constrained wp-container-core-group-is-layout-1dc30360 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--x-large);padding-right:0;padding-bottom:var(--wp--preset--spacing--large);padding-left:0;--octopods-group-overlay-color:#F7F8FD;--octopods-group-z-index:2\">\n<div class=\"wp-block-group has-base-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-3d8b3269 wp-block-group-is-layout-constrained\" style=\"border-radius:20px;padding-top:var(--wp--preset--spacing--large);padding-right:var(--wp--preset--spacing--large);padding-bottom:var(--wp--preset--spacing--large);padding-left:var(--wp--preset--spacing--large);box-shadow:var(--wp--preset--shadow--natural)\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-d9c2617f wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:var(--wp--preset--spacing--large);padding-top:0;padding-bottom:0\">\n<h2 class=\"wp-block-heading has-text-align-center has-contrast-color has-text-color has-link-color wp-elements-3\">Analyse d\u00e9taill\u00e9e<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline is-animated icare-timeline-force-left\" data-animation=\"slideInBottom\" data-filling=\"true\"><div class=\"wp-block-getwid-content-timeline__line\"><div class=\"wp-block-getwid-content-timeline__bar has-background has-secondary-background-color\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline__wrapper\">\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-4\"><strong>\u00c9tape 1 | D\u00e9tection de l\u2019anomalie<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">Plusieurs points de mesure ont r\u00e9v\u00e9l\u00e9 une augmentation progressive des niveaux vibratoires globaux, comme le montre le <a href=\"https:\/\/www.icareweb.com\/fr\/solutions\/maintenance-predictive\/plateforme\/\">tableau de bord I-see\u2122<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border is-style-default\" style=\"margin-top:0;margin-bottom:0\"><img loading=\"lazy\" decoding=\"async\" width=\"583\" height=\"223\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-velocity-rms-trend-alarm-threshold-exceedance-01-v1.png\" alt=\"Vibration velocity trend showing rising RMS levels exceeding alarm thresholds on rotating equipment]\" class=\"wp-image-99123\" style=\"border-radius:20px;width:600px;height:auto\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">ventilateur, atteignant des valeurs allant jusqu\u2019\u00e0 32 mm\/s RMS, ce qui indique un comportement anormal de la machine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette tendance a d\u00e9clench\u00e9 une analyse approfondie men\u00e9e par un sp\u00e9cialiste en analyse vibratoire d\u2019I-care afin d\u2019identifier l\u2019origine de l\u2019anomalie.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-5\">\u00c9tape 2 | Analyse initiale et hypoth\u00e8se<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-ad28b7db wp-block-group-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--x-small);margin-bottom:var(--wp--preset--spacing--x-small)\">\n<p class=\"wp-block-paragraph\">Le spectre vibratoire mesur\u00e9 sur le ventilateur a r\u00e9v\u00e9l\u00e9 un pic dominant \u00e0 la fr\u00e9quence de rotation du ventilateur (1\u00d7). Bien que cette composante puisse \u00eatre associ\u00e9e \u00e0 plusieurs types de d\u00e9fauts, sa pr\u00e9dominance a conduit \u00e0 envisager un balourd comme hypoth\u00e8se initiale.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border is-style-default\" style=\"margin-top:0;margin-bottom:0\"><img loading=\"lazy\" decoding=\"async\" width=\"876\" height=\"544\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-1x-running-speed-dominant-peak-01-v1.png\" alt=\"Vibration spectrum trend showing dominant 1\u00d7 running speed peak\" class=\"wp-image-99131\" style=\"border-radius:20px;width:600px;height:auto\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-1x-running-speed-dominant-peak-01-v1.png 876w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-1x-running-speed-dominant-peak-01-v1-600x373.png 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-1x-running-speed-dominant-peak-01-v1-768x477.png 768w\" sizes=\"auto, (max-width: 876px) 100vw, 876px\" \/><\/figure>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Cette composante \u00e9tait particuli\u00e8rement marqu\u00e9e aux points de mesure situ\u00e9s du c\u00f4t\u00e9 oppos\u00e9 \u00e0 l\u2019entra\u00eenement du ventilateur, ce qui correspondait aux emplacements o\u00f9 les niveaux vibratoires globaux les plus \u00e9lev\u00e9s avaient \u00e9t\u00e9 enregistr\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 ce stade, la signature vibratoire \u00e9tait caract\u00e9ristique d\u2019un d\u00e9s\u00e9quilibre de type balourd, constituant ainsi l\u2019hypoth\u00e8se initiale pour expliquer le comportement observ\u00e9.<\/p>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-6\">\u00c9tape 3 | Affinement du diagnostic<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">Une analyse approfondie des signaux vibratoires a r\u00e9v\u00e9l\u00e9 des ph\u00e9nom\u00e8nes d\u2019impact distincts dans les signaux temporels, notamment aux points de mesure o\u00f9 la composante 1\u00d7 \u00e9tait moins dominante.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border is-style-default\" style=\"margin-top:0;margin-bottom:0\"><img loading=\"lazy\" decoding=\"async\" width=\"860\" height=\"512\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-time-waveform-repetitive-impact-pattern-increasing-trend-01-v1.png\" alt=\"Time waveform trend showing repetitive impact patterns increasing over time\" class=\"wp-image-99187\" style=\"border-radius:20px;width:600px;height:auto\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-time-waveform-repetitive-impact-pattern-increasing-trend-01-v1.png 860w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-time-waveform-repetitive-impact-pattern-increasing-trend-01-v1-600x357.png 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-time-waveform-repetitive-impact-pattern-increasing-trend-01-v1-768x457.png 768w\" sizes=\"auto, (max-width: 860px) 100vw, 860px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ces signatures d\u2019impact ne pouvaient pas \u00eatre expliqu\u00e9es uniquement par un balourd et r\u00e9v\u00e9laient la pr\u00e9sence d\u2019un probl\u00e8me m\u00e9canique suppl\u00e9mentaire.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border is-style-default\" style=\"margin-top:0;margin-bottom:0\"><img loading=\"lazy\" decoding=\"async\" width=\"872\" height=\"511\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-low-frequency-peak-increasing-trend-01-v1.png\" alt=\"Vibration spectrum trend showing increasing low-frequency peaks over time\" class=\"wp-image-99194\" style=\"border-radius:20px;width:600px;height:auto\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-low-frequency-peak-increasing-trend-01-v1.png 872w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-low-frequency-peak-increasing-trend-01-v1-600x352.png 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/vibration-spectrum-low-frequency-peak-increasing-trend-01-v1-768x450.png 768w\" sizes=\"auto, (max-width: 872px) 100vw, 872px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Parall\u00e8lement, le spectre vibratoire pr\u00e9sentait une augmentation des composantes harmoniques autour de la fr\u00e9quence de rotation, caract\u00e9ristique d\u2019un m\u00e9canisme de d\u00e9gradation impliquant un jeu m\u00e9canique excessif.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La combinaison des ph\u00e9nom\u00e8nes d\u2019impact et de l\u2019amplification des harmoniques a conduit l\u2019analyste \u00e0 affiner son diagnostic en privil\u00e9giant l\u2019hypoth\u00e8se d\u2019un desserrage m\u00e9canique, potentiellement li\u00e9 aux forces g\u00e9n\u00e9r\u00e9es par le balourd initial.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-7\">\u00c9tape 4 | Recommandations et gestion des risques<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">Compte tenu de l\u2019augmentation rapide des niveaux vibratoires globaux et de l\u2019\u00e9volution des signatures spectrales et temporelles, I-care a recommand\u00e9 de proc\u00e9der \u00e0 une inspection du ventilateur dans les plus brefs d\u00e9lais, en lui accordant un niveau de priorit\u00e9 \u00e9lev\u00e9.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 ce stade, la gravit\u00e9 des vibrations observ\u00e9es ne n\u00e9cessitait pas encore un arr\u00eat imm\u00e9diat, mais leur \u00e9volution indiquait clairement que la machine ne pouvait plus continuer \u00e0 fonctionner sans surveillance \u00e9troite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un arr\u00eat de production \u00e9tant d\u00e9j\u00e0 programm\u00e9 pendant la p\u00e9riode de No\u00ebl, il a \u00e9t\u00e9 d\u00e9cid\u00e9 de maintenir le ventilateur en fonctionnement sous surveillance quotidienne jusqu\u2019\u00e0 cette p\u00e9riode de maintenance. Cette d\u00e9cision a permis de planifier l\u2019intervention sans entra\u00eener d\u2019arr\u00eat de production suppl\u00e9mentaire.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-e627be86 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-8\">\u00c9tape 5 | Surveillance et \u00e9volution du d\u00e9faut<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">Conform\u00e9ment aux recommandations, le ventilateur a fait l\u2019objet d\u2019une surveillance quotidienne \u00e9troite afin de suivre l\u2019\u00e9volution du d\u00e9faut et d\u2019\u00e9valuer les risques li\u00e9s \u00e0 la poursuite de son fonctionnement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Au cours des semaines suivantes, le comportement vibratoire s\u2019est rapidement d\u00e9grad\u00e9. L\u2019augmentation des niveaux vibratoires globaux, associ\u00e9e \u00e0 l\u2019\u00e9volution des signatures spectrales et temporelles, a confirm\u00e9 la progression rapide du d\u00e9faut.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La premi\u00e8re d\u00e9tection et le premier rapport ont \u00e9t\u00e9 \u00e9mis le 29 novembre. La situation a atteint un niveau d\u2019urgence le 21 d\u00e9cembre. Sur la base de la vitesse de d\u00e9gradation observ\u00e9e, le d\u00e9lai entre le premier signalement urgent et une \u00e9ventuelle d\u00e9faillance a \u00e9t\u00e9 estim\u00e9 \u00e0 environ 15 jours.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"233\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/spectral-waveform-pattern-vibration-01-v1.png\" alt=\"Peak-to-peak vibration trend showing rapid increase above alarm threshold, indicating accelerating fault over time\" class=\"wp-image-99202\" style=\"border-radius:20px;box-shadow:var(--wp--preset--shadow--natural);width:600px;height:auto\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ce suivi rapproch\u00e9 a \u00e9t\u00e9 essentiel pour permettre au site de maintenir le ventilateur en fonctionnement jusqu\u2019\u00e0 l\u2019arr\u00eat de production programm\u00e9 pour No\u00ebl, tout en surveillant \u00e9troitement l\u2019\u00e9volution du d\u00e9faut.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-e627be86 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-9\">\u00c9tape 6 | Inspection et intervention corrective<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">L\u2019inspection a confirm\u00e9 la pr\u00e9sence d\u2019un jeu entre la bague int\u00e9rieure du roulement et l\u2019arbre, validant ainsi le diagnostic \u00e9tabli gr\u00e2ce \u00e0 l\u2019<a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/quest-ce-que-analyse-vibratoire-maintenance-predictive\/\">analyse vibratoire<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"438\" height=\"433\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/metal-shaft-surface-wear-scoring-discoloration-01-v1.png\" alt=\"Metal shaft surface showing localized wear, discoloration, and scoring marks indicating mechanical degradation\" class=\"wp-image-99209\" style=\"border-radius:20px;box-shadow:var(--wp--preset--shadow--natural);width:600px;height:auto\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Pour \u00e9liminer le d\u00e9faut, l\u2019\u00e9quipe de maintenance a proc\u00e9d\u00e9 au remplacement de l\u2019arbre ainsi que des roulements associ\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019intervention a \u00e9t\u00e9 r\u00e9alis\u00e9e pendant l\u2019arr\u00eat de production programm\u00e9, ce qui a permis de r\u00e9soudre le probl\u00e8me sans perturber la production.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-getwid-content-timeline-item has-card-right\" style=\"margin-bottom:50px\"><div class=\"wp-block-getwid-content-timeline-item__wrapper\"><div class=\"wp-block-getwid-content-timeline-item__card\"><div class=\"wp-block-getwid-content-timeline-item__card-wrapper\"><div class=\"wp-block-getwid-content-timeline-item__content-wrapper\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-e627be86 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-secondary-color has-text-color has-link-color wp-elements-10\">\u00c9tape 7 | V\u00e9rification apr\u00e8s intervention<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4bd015aa wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">\u00c0 la suite de l\u2019intervention, les niveaux vibratoires sont revenus \u00e0 leurs valeurs de r\u00e9f\u00e9rence, confirmant la disparition de l\u2019anomalie pr\u00e9c\u00e9demment d\u00e9tect\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La comparaison des donn\u00e9es avant et apr\u00e8s l\u2019intervention a r\u00e9v\u00e9l\u00e9 une nette diminution des niveaux vibratoires globaux ainsi que la disparition des ph\u00e9nom\u00e8nes d\u2019impact, confirmant l\u2019efficacit\u00e9 de l\u2019action corrective.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La surveillance continue au cours des mois suivant la r\u00e9paration a confirm\u00e9 la stabilit\u00e9 des conditions de fonctionnement, sans r\u00e9apparition de signatures vibratoires anormales.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__point\" style=\"margin-left:50px;margin-right:50px\" data-point-color=\"#f7941d\"><div class=\"wp-block-getwid-content-timeline-item__point-content\"><\/div><\/div><div class=\"wp-block-getwid-content-timeline-item__meta\"><\/div><\/div><\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"min-height:50vh;margin-top:-50vh;--octopods-divider-shape-color:#F7F8FD;--octopods-divider-icon-color:;--octopods-divider-icon-size:20px;--octopods-divider-icon-align:center;--octopods-divider-icon-justify:center\" class=\"wp-block-octopods-divider alignfull\"><div class=\"wp-block-octopods-divider__shape\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"angle-layered_svg__octopods-divider-svg angle-layered_svg__octopods-divider-svg--angle-layered\" preserveAspectRatio=\"none\" viewBox=\"0 0 2600 129\"><path d=\"M2600 64 0 128v1h2600z\"><\/path><path d=\"M0 129h2600V64H0z\" opacity=\"0.5\"><\/path><path d=\"M2600 64 0 0v129h2600z\" opacity=\"0.5\"><\/path><\/svg><\/div><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-neutral-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-544032e9 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--x-large);padding-right:0;padding-bottom:var(--wp--preset--spacing--large);padding-left:0;box-shadow:none\">\n<div class=\"wp-block-group has-base-color has-contrast-background-color has-text-color has-background has-link-color wp-elements-11 has-global-padding is-layout-constrained wp-container-core-group-is-layout-2fa07ba7 wp-block-group-is-layout-constrained\" style=\"border-radius:20px;padding-top:var(--wp--preset--spacing--large);padding-right:var(--wp--preset--spacing--large);padding-bottom:var(--wp--preset--spacing--large);padding-left:var(--wp--preset--spacing--large);box-shadow:var(--wp--preset--shadow--natural)\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">R\u00e9sultats<\/h2>\n\n\n\n<p class=\"has-secondary-color has-text-color has-link-color has-large-font-size wp-elements-12 wp-block-paragraph\"><strong><strong>Une d\u00e9faillance critique du syst\u00e8me CVC \u00e9vit\u00e9e, avec des pertes de production potentielles estim\u00e9es \u00e0 plusieurs centaines de milliers de dollars par jour<\/strong><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-e8af4a40 wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\">Au-del\u00e0 des dommages m\u00e9caniques, une d\u00e9faillance inattendue aurait entra\u00een\u00e9 un arr\u00eat impr\u00e9vu du syst\u00e8me CVC, compromettant les conditions de ma\u00eetrise de l\u2019air dans la zone de production pharmaceutique et risquant de provoquer le rejet d\u2019un lot de production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avec un impact financier estim\u00e9 \u00e0 plusieurs centaines de milliers de dollars, les cons\u00e9quences potentielles d\u2019une d\u00e9faillance impr\u00e9vue \u00e9taient particuli\u00e8rement importantes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gr\u00e2ce \u00e0 la surveillance continue assur\u00e9e par <a href=\"https:\/\/www.icareweb.com\/fr\/solutions\/maintenance-predictive\/capteurs\/\">Wi-care\u2122<\/a> et I-see\u2122, les experts d\u2019I-care ont pu suivre quotidiennement l\u2019\u00e9volution du d\u00e9faut et \u00e9valuer pr\u00e9cis\u00e9ment sa gravit\u00e9. Il a ainsi \u00e9t\u00e9 possible de maintenir le ventilateur en fonctionnement en toute s\u00e9curit\u00e9 jusqu\u2019\u00e0 l\u2019arr\u00eat programm\u00e9 pour No\u00ebl, durant lequel la r\u00e9paration a \u00e9t\u00e9 effectu\u00e9e dans des conditions ma\u00eetris\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ce cas illustre clairement la valeur ajout\u00e9e de la surveillance continue face \u00e0 des d\u00e9fauts \u00e9voluant rapidement. Alors que des inspections p\u00e9riodiques auraient pu, selon leur fr\u00e9quence, passer \u00e0 c\u00f4t\u00e9 de cette courte p\u00e9riode pr\u00e9c\u00e9dant la d\u00e9faillance, l\u2019association d\u2019une collecte continue des donn\u00e9es et d\u2019une analyse experte a permis de d\u00e9tecter le probl\u00e8me \u00e0 un stade pr\u00e9coce, de suivre \u00e9troitement son \u00e9volution et de le r\u00e9soudre sans interrompre la production.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/www.icareweb.com\/fr\/solutions\/maintenance-predictive\/plateforme\/\">R\u00e9server une d\u00e9mo<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n\n\n<div class=\"wp-block-group alignfull has-neutral-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-a8d382cc wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--x-large);padding-bottom:var(--wp--preset--spacing--large);--octopods-group-z-index:2\">\n<div class=\"wp-block-group is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-33ae0263 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-e627be86 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-primary-color has-text-color has-link-color wp-elements-123\">D\u00e9couvrez nos<\/h3>\n\n\n\n<h2 class=\"wp-block-heading\">Cas techniques<\/h2>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-global-padding is-content-justification-right is-layout-constrained wp-container-core-group-is-layout-f77a4fac wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-query is-layout-flow wp-block-query-is-layout-flow\">\n\t\t\t<div\n\t\t\t\tclass=\"octopods-post-template-swiper swiper\"\n\t\t\t\tdata-octopods-slider-slides-per-view=\"4\"\n\t\t\t\tdata-octopods-slider-effect=\"slide\"\n\t\t\t\tdata-octopods-slider-autoplay=\"false\"\n\t\t\t\tdata-octopods-slider-autoplay-delay=\"5000\"\n\t\t\t\tdata-octopods-slider-loop=\"true\"\n\t\t\t\tdata-octopods-slider-navigation=\"true\"\n\t\t\t\tdata-octopods-slider-pagination=\"\"\n\t\t\t\tdata-octopods-slider-speed=\"600\"\n\t\t\t\tstyle=\"\"\n\t\t\t>\n\n\t\t\t\t<ul class=\"wp-block-post-template is-layout-flow wp-block-post-template-is-layout-flow\"><li class=\"wp-block-post post-161253 resource type-resource status-publish has-post-thumbnail industry-agroalimentaire-boissons topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/detection-poligonisation-usure-rouleaux-broyeur-flocons-surveillance-vibratoire-continue\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"D\u00e9tection de la poligonisation avant une usure s\u00e9v\u00e8re des rouleaux dans un broyeur \u00e0 flocons gr\u00e2ce \u00e0 une surveillance vibratoire continue\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/06\/technical-case-example-wireless-vibration-sensors-flaker-mill-01-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-124 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/detection-poligonisation-usure-rouleaux-broyeur-flocons-surveillance-vibratoire-continue\/\" target=\"_self\" >D\u00e9tection de la poligonisation avant une usure s\u00e9v\u00e8re des rouleaux dans un broyeur \u00e0 flocons gr\u00e2ce \u00e0 une surveillance vibratoire continue<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-132542 resource type-resource status-publish has-post-thumbnail industry-agroalimentaire-boissons topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/fluting-electrique-moteur-compresseur-analyse-vibratoire\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"D\u00e9tection pr\u00e9coce du fluting \u00e9lectrique sur un moteur de compresseur entra\u00een\u00e9 par variateur de vitesse gr\u00e2ce \u00e0 l&#8217;analyse vibratoire\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-screw-compressor-01-v1-1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-125 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/fluting-electrique-moteur-compresseur-analyse-vibratoire\/\" target=\"_self\" >D\u00e9tection pr\u00e9coce du fluting \u00e9lectrique sur un moteur de compresseur entra\u00een\u00e9 par variateur de vitesse gr\u00e2ce \u00e0 l&#8217;analyse vibratoire<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-172760 resource type-resource status-publish has-post-thumbnail industry-pharmaceutique topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/prevention-panne-ventilateur-cvc-pharmaceutique-analyse-vibratoire-maintenance-predictive\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"Comment l\u2019analyse vibratoire a permis d\u2019\u00e9viter une panne critique d\u2019un ventilateur CVC dans une usine pharmaceutique\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2026\/04\/technical-case-example-wireless-vibration-sensors-centrifugal-fan-01-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-126 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/prevention-panne-ventilateur-cvc-pharmaceutique-analyse-vibratoire-maintenance-predictive\/\" target=\"_self\" >Comment l\u2019analyse vibratoire a permis d\u2019\u00e9viter une panne critique d\u2019un ventilateur CVC dans une usine pharmaceutique<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-71101 resource type-resource status-publish has-post-thumbnail industry-eolien topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/prevention-panne-multiplicateur-eolienne\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"Pr\u00e9vention d\u2019une panne de multiplicateur \u00e9olien \u00e0 200 000 $ gr\u00e2ce \u00e0 la maintenance pr\u00e9dictive\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-02-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-127 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/prevention-panne-multiplicateur-eolienne\/\" target=\"_self\" >Pr\u00e9vention d\u2019une panne de multiplicateur \u00e9olien \u00e0 200 000 $ gr\u00e2ce \u00e0 la maintenance pr\u00e9dictive<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-69740 resource type-resource status-publish has-post-thumbnail industry-agroalimentaire-boissons topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/laminoir-a-basse-vitesse\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"D\u00e9faillance d\u2019un laminoir \u00e0 basse vitesse \u00e9vit\u00e9e, avec plus de $500 000 \u00e9conomis\u00e9s\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/12\/featured-image-01-v01-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-128 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/laminoir-a-basse-vitesse\/\" target=\"_self\" >D\u00e9faillance d\u2019un laminoir \u00e0 basse vitesse \u00e9vit\u00e9e, avec plus de $500 000 \u00e9conomis\u00e9s<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-66012 resource type-resource status-publish has-post-thumbnail topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/detection-defaut-roulement-soufflante\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"La d\u00e9tection d\u2019un d\u00e9faut de roulement sur un ventilateur a permis d\u2019\u00e9viter un risque d\u2019incendie\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/rotaryblower-01-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-129 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/detection-defaut-roulement-soufflante\/\" target=\"_self\" >La d\u00e9tection d\u2019un d\u00e9faut de roulement sur un ventilateur a permis d\u2019\u00e9viter un risque d\u2019incendie<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-65411 resource type-resource status-publish has-post-thumbnail industry-eolien topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/economie-180000-panne-turbine-eolienne\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-600x338.png\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"180.000$ \u00e9conomis\u00e9s gr\u00e2ce \u00e0 la d\u00e9tection pr\u00e9coce d\u2019une d\u00e9faillance du roulement principal d\u2019une \u00e9olienne\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-600x338.png 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-1280x720.png 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-768x432.png 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-1536x864.png 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1-1200x675.png 1200w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/featured-windnogear-01-v1.png 1920w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-130 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/economie-180000-panne-turbine-eolienne\/\" target=\"_self\" >180.000$ \u00e9conomis\u00e9s gr\u00e2ce \u00e0 la d\u00e9tection pr\u00e9coce d\u2019une d\u00e9faillance du roulement principal d\u2019une \u00e9olienne<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-65180 resource type-resource status-publish has-post-thumbnail topic-analyse-vibratoire topic-maintenance-predictive post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/a-prevenu-une-defaillance-cachee-et-a-evite-un-arret-couteux-de-la-pompe\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"Fissur\u00e9, mais pas bris\u00e9 : comment I-care a d\u00e9tect\u00e9 une d\u00e9faillance cach\u00e9e d\u2019un accouplement\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/11\/asset-circulation-pump-01-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-131 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/a-prevenu-une-defaillance-cachee-et-a-evite-un-arret-couteux-de-la-pompe\/\" target=\"_self\" >Fissur\u00e9, mais pas bris\u00e9 : comment I-care a d\u00e9tect\u00e9 une d\u00e9faillance cach\u00e9e d\u2019un accouplement<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><li class=\"wp-block-post post-61252 resource type-resource status-publish has-post-thumbnail industry-exploitation-miniere topic-analyse-vibratoire post-cat-cas-techniques\">\n\n<div class=\"wp-block-group has-border-color has-base-background-color has-background is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-945f1aea wp-block-group-is-layout-flex\" style=\"border-color:#8d919c1a;border-width:1px;border-radius:20px;min-height:100%;margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:hidden;--octopods-group-box-shadow:rgba(48,75,130,.15) 5px 0px 50px 0px;--octopods-group-position:relative;aspect-ratio:unset;\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;--octopods-group-overflow:visible;--octopods-group-position:relative\">\n<div class=\"wp-block-group is-style-default has-base-background-color has-background is-layout-flow wp-block-group-is-layout-flow\" style=\"border-top-right-radius:10px;margin-top:0;margin-bottom:0;padding-top:0.5rem;padding-right:var(--wp--preset--spacing--small);padding-bottom:0.5rem;padding-left:var(--wp--preset--spacing--small);--octopods-group-z-index:2;--octopods-group-position:absolute;--octopods-group-bottom:-1px;--octopods-group-left:-1px\"><div style=\"font-size:0.8rem;font-style:normal;font-weight:500\" class=\"taxonomy-post-cat wp-block-post-terms\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/cas-techniques\/\" rel=\"tag\">Cas Techniques<\/a><\/div><\/div>\n\n\n<figure style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/moulin-de-rebroyage\/\" target=\"_self\" ><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-600x338.jpg\" class=\"attachment-octopods-grid size-octopods-grid wp-post-image\" alt=\"Plus d\u2019un million de dollars de pertes \u00e9vit\u00e9es sur un broyeur\" style=\"border-top-left-radius:0.33rem;border-top-right-radius:0.33rem;border-bottom-left-radius:0rem;border-bottom-right-radius:0rem;aspect-ratio:3\/2;width:100%;object-fit:cover;\" srcset=\"https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-600x338.jpg 600w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-1280x720.jpg 1280w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-1920x1080.jpg 1920w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-768x432.jpg 768w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-1536x864.jpg 1536w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-2048x1152.jpg 2048w, https:\/\/www.icareweb.com\/wp-content\/uploads\/2025\/10\/regrind-mill-featured-01-v1-1200x675.jpg 1200w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-group wp-container-content-9cfa9a5a is-vertical is-content-justification-stretch is-layout-flex wp-container-core-group-is-layout-cdb9a1b4 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--small);padding-right:var(--wp--preset--spacing--small);padding-bottom:var(--wp--preset--spacing--small);padding-left:var(--wp--preset--spacing--small)\"><h3 style=\"font-size:clamp(0.875rem, 0.875rem + ((1vw - 0.2rem) * 0.381), 1.18rem);line-height:1.3\" class=\"has-link-color wp-elements-132 wp-block-post-title\"><a href=\"https:\/\/www.icareweb.com\/fr\/ressources\/maintenance-predictive\/moulin-de-rebroyage\/\" target=\"_self\" >Plus d\u2019un million de dollars de pertes \u00e9vit\u00e9es sur un broyeur<\/a><\/h3><\/div>\n<\/div>\n\n<\/li><\/ul>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"swiper-button-prev\"><\/div>\n\t\t\t\t\t<div class=\"swiper-button-next\"><\/div>\n\t\t\t\t\n            <\/div>\n\n\t\t\t\n\n\n<div style=\"height:var(--wp--preset--spacing--small)\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-neutral-accent-background-color has-background has-global-padding is-layout-constrained wp-container-core-group-is-layout-f17c0436 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--x-large);padding-bottom:0\">\n<div class=\"wp-block-group alignfull has-base-color has-text-color has-link-color wp-elements-133 has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:var(--wp--preset--spacing--large);padding-bottom:var(--wp--preset--spacing--large);--octopods-group-overlay-gradient:linear-gradient(339deg,rgba(32,39,97,0.82) 0%,rgb(14,17,50) 16%);--octopods-group-background-image:url(https:\/\/www.icareweb.com\/wp-content\/uploads\/2024\/08\/dscf8660.jpg);--octopods-group-background-position:50% 50%;--octopods-group-background-size:cover;--octopods-group-background-repeat:no-repeat;--octopods-group-background-attachment:scroll\">\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-container-core-group-is-layout-4cbcfbb4 wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading has-text-align-center\">Nos solutions couvrent tous les \u00e9quipements, y compris les v\u00f4tres.<\/h2>\n\n\n\n<p class=\"has-text-align-center has-large-font-size wp-block-paragraph\">Pr\u00eat \u00e0 am\u00e9liorer votre efficacit\u00e9 op\u00e9rationnelle ?<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-4927ffd3 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background has-border-color has-secondary-border-color wp-element-button\" href=\"https:\/\/www.icareweb.com\/fr\/book-a-meeting\/\">Parler \u00e0 un expert<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Comment l\u2019analyse vibratoire a permis d\u2019\u00e9viter une panne critique d\u2019un ventilateur CVC dans une usine pharmaceutique \u00c9quipement : Ventilateur centrifuge \u00e0 entra\u00eenement par courroie (CVC) Technologie : Analyse vibratoire Surveillance : Wi-care\u2122 | I-see\u2122 Pr\u00e9sentation de l\u2019\u00e9quipement L\u2019\u00e9quipement surveill\u00e9 est un ventilateur centrifuge \u00e0 entra\u00eenement par courroie int\u00e9gr\u00e9 \u00e0 un syst\u00e8me critique de chauffage, ventilation [&hellip;]<\/p>\n","protected":false},"featured_media":99108,"menu_order":0,"template":"ressource-blank-template","meta":{"_acf_changed":false,"content-type":"","inline_featured_image":false},"knowledge-industries":[366],"knowledge-topics":[391],"knowledge-types":[94],"class_list":["post-172760","resource","type-resource","status-publish","has-post-thumbnail","industry-pharmaceutique","topic-analyse-vibratoire","post-cat-cas-techniques"],"acf":[],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/knowledge\/172760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/knowledge"}],"about":[{"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/types\/resource"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/media\/99108"}],"wp:attachment":[{"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/media?parent=172760"}],"wp:term":[{"taxonomy":"industry","embeddable":true,"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/knowledge-industries?post=172760"},{"taxonomy":"topic","embeddable":true,"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/knowledge-topics?post=172760"},{"taxonomy":"post-cat","embeddable":true,"href":"https:\/\/www.icareweb.com\/fr\/wp-json\/wp\/v2\/knowledge-types?post=172760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}